Description

Versatile roof and wall cladding featuring bold, trapezoidal ribs and subtle fluting in the pans. Ideal for commercial, industrial and residential buildings.

  • Long spanning cladding permitting wide support spacing
  • Can be used with TRIM-KLIP™ end and expansion joint system
  • Nominal cover width: 762mm
  • Minimum roof slope: 2°

Technical Specifications

Schematic

Lengths

Sheets are supplied custom cut to length. Minimum and maximum lengths apply. Please contact your nearest LYSAGHT® office for your region for more information.

Tolerance

Length: +0mm, -15mm
Width: +4mm, -4mm

Material Specification

Next generation ZINCALUME® aluminium/zinc/ magnesium alloy coated steel complies with AS1397:2011 G550, AM125 (550 MPa minimum yield stress, 125 g/m2 minimum coating mass).

COLORBOND® steel is prepainted steel for exterior roofing and walling. It is the most widely used. The painting complies with AS/NZS 2728:2013 and the steel base is an aluminium/zinc alloy-coated steel complying with AS 1397:2011. Minimum yield strengths are G550 (550MPa), or G300 (300MPa) depending on profile. Minimum coating mass is AM100 (100g/m2).

COLORBOND® Metallic steel is prepainted steel for superior aesthetic qualities displaying a metallic sheen.

COLORBOND® Ultra steel is prepainted steel for severe coastal or industrial environments (generally within about 100-200 metres of the source). The painting complies with AS/NZS 2728:2013 and the steel base is an aluminium/ zinc alloy-coated steel complying with AS 1397:2011. Minimum coating mass is AM150 (150g/m2).

COLORBOND® Stainless steel is pre-painted steel and is used for severe and coastal environments. The painting complies with AS/NZS 2728:2013 and the steel base is a stainless steel complying with AISI/ASTM Type 430; UNS No. S43000.

Masses

Finish BMT Mass
(mm) kg/m kg/m2 m2/t
ZINCALUME® 0.42 3.26 4.28 234
COLORBOND® 0.42 3.32 4.35 230
ZINCALUME® 0.48 3.70 4.86 206
COLORBOND® 0.48 3.76 4.93 203

Span Table

The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992.

Roof spans consider both resistance to wind pressure and light roof traffic (traffic arising from incidental maintenance). Wall spans consider resistance to wind pressure only.

The pressure considered is based on buildings up to 10m high in Region B, Terrain Category 3. For further details Download LYSAGHT TRIMDEK® Design and Installation Guide.

Maximum Support Spacings (mm)
Types of Span BMT (mm)
0.42 0.48
Roofs
Single Span 1100 1600
End Span 1300 1850
Internal Span 1900 2600
Unstiffened Eaves Overhang 150 200
Stiffened Eaves Overhang 300 350
Walls
Single Span 2400 2700
End Span 3000 3000
Internal Span 3000 3000
Overhang 150 200

Capacity & Load Tables

The limit state wind pressure capacity table can be viewed in the LYSAGHT TRIMDEK® brochure. Download LYSAGHT TRIMDEK® Design and Installation Guide.

This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.

For correct specification and installation of Lysaght roofing and walling products in cyclonic areas, please download LYSAGHT® Cyclonic Area Design Manual.

Roof Drainage Capacity

LYSAGHT® Roofing & Walling Installation Manual. - Chapter 2 Design Preliminaries - to view Table 2.14.1, Maximum Roof Lengths for Drainage.

NCC of Australia Compliance

LYSAGHT® products comply with the National Construction Code of Australia (NCC).

Downloads

CAD Drawings

LYSAGHT TRIMDEK® (AutoCAD) DWG (0.0 MB). Last updated 28 Oct 2015

LYSAGHT TRIMDEK® (AutoCAD) DXF (0.0 MB). Last updated 28 Oct 2015

LYSAGHT TRIMDEK® (Microstation) DGN (0.0 MB). Last updated 28 Oct 2015

LYSAGHT TRIMDEK® (Revit) RFA (0.1 MB). Last updated 28 Oct 2015

Brochures & Catalogues

LYSAGHT® Build On Inspiration PDF (8.4 MB). Last updated 16 May 2019

LYSAGHT® Walling Brochure PDF (4.4 MB). Last updated 13 Jul 2017

User Guides & Manuals

LYSAGHT TRIMDEK® Design and Installation Guide PDF (0.4 MB). Last updated 18 Oct 2018

LYSAGHT® Architectural Detailing & Flashing Manual PDF (3.9 MB). Last updated 2 Jul 2019

LYSAGHT® Cyclonic Area Design Manual PDF (1.4 MB). Last updated 23 Jan 2019

LYSAGHT® Walling Solutions Guide PDF (2.3 MB). Last updated 28 May 2018

LYSAGHT® Roofing & Walling Installation Manual PDF (4.0 MB). Last updated 11 Mar 2019

Order hard copies

Availability

New South Wales & ACT
Available
Northern Territory
Available
Queensland
Available
South Australia
Available
Tasmania
Available
Victoria
Available
Available
Filled
Available
Outlined
Not Available

Colour Range

STANDARD COLOUR RANGE

  1. Basalt®
  2. Classic Cream™
  3. Cottage Green®
  4. Cove™
  5. Deep Ocean®
  6. Dune®
  7. Evening Haze®
  8. Gully™
  9. Ironstone®
  10. Jasper®
  11. Mangrove®
  12. Manor Red®
  13. Monument®
  14. Night Sky®
  15. Pale Eucalypt®
  16. Paperbark®
  17. Shale Grey™
  18. Surfmist®
  19. Terrain®
  20. Wallaby®
  21. Windspray®
  22. Woodland Grey®

ULTRA COLOUR RANGE

  1. Dune®
  2. Monument®
  3. Surfmist®
  4. Wallaby®
  5. Windspray®
  6. Woodland Grey®

MATT COLOUR RANGE

  1. Basalt®
  2. Dune®
  3. Monument®
  4. Shale Grey™
  5. Surfmist®

METALLIC COLOUR RANGE

  1. Aries™
  2. Astro™
  3. Celestian™
  4. Cosmic™
  5. Galactic™
  6. Rhea™

DOUBLE SIDED ROOFING COLOUR RANGE

  1. Classic Cream™/ Classic Cream™ gloss
  2. Manor Red®/ Classic Cream™ gloss
  3. Paperbark®/ Paperbark® gloss
  4. Woodland Grey®/ Classic Cream™ gloss

Unpainted Steel Range

  1. ZINCALUME® steel

Pricing

Pricing for all our products varies based on availability and quantity.

Questions?

Phone (Mon-Fri, 9AM-5PM AEST/AEDT):

1800 641 417